Abstract

The aim of this study is to compare the osseointegration behavior of titanium (Ti) and titanium-zirconium (TiZr) implants in ovariectomized (OVX) rabbits. Twelve ovariectomized New Zealand rabbits submitted to a hypocalcic diet and 12 sham-aged rabbits were used. After the bone mass loss induction period, TiZr or Ti implants both benefiting from a SLActive surface treatment were randomly inserted in the tibia and femur of each animal. The total of 24 rabbits were divided in four groups (n=6): SHAM+Ti, OVX+Ti, SHAM+TiZr,OVX+TiZr. The animals were respectively sacrificed 3 and 6weeks after dental implant placement. Six implants in each group at each time point were subjected to removal torque testing, and the remaining implants were prepared for histomorphometric analysis. At the end of the healing period, all implants were osseointegrated. The removal torque value of the SHAM-TiZr group was significantly higher than those of the SHAM-Ti group (P<0.001). The removal torque of the OVX-Ti group was significantly lower than those of the OVX-TiZr group. All groups demonstrated an increase in the peak torque value after 6weeks: 46.0 and 50.8Ncm for the OVX and the SHAM animals, respectively, in the case where Ti implants were used. When TiZr implants were inserted, the values reached 60.7 and 76.2Ncm with a similar group configuration. The BIC and the BA/TA analysis showed an increase between week 3 and 6 in the case of nonovariectomized animals. From week 3 to 6, the BIC went from 37.1±14.3 to 47.7±8.7 for the SHAM+Ti group and from 37.6±10.9 to 50.4±11 for the SHAM+TiZr group. The BIC values were not significantly different between groups. The parameters intended to be representative of the bone morphology (BIC & BATA) did not help to discriminate between Ti and TiZr which appeared to behave similarly in this experimental model. However, the removal torque values for the TiZr group were statistically higher than those of the Ti group in both the SHAM and the ovariectomized animals. That likely reflected an increased quality of bone around the TiZr implants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.