Abstract

The behavior of iridium- and osmium-coated dispenser cathodes in background pressures of oxygen and water vapor is discussed. Poisoning is predominantly chemical in nature and occurs at significantly lower pressures than would be expected for physical sputtering damage to the cathode surface. Measurements to determine the maximum background pressure in which the cathode can maintain their full emission capability are presented. The osmium-coated cathode has greater resistance to poisoning than the iridium-coated both at room and operating temperatures. The coated cathodes can operate in about three times as great a pressure of water vapor as oxygen. The results suggest ways that these cathodes can be optimized in nonideal vacuum. They also suggest that it should be possible to design an osmium-coated that will be able to emit fully 1310 K to about 5*10/sup -8/ torr of water vapor.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.