Abstract
Initial block in the His-Purkinje system was demonstrated in 17 of 71 patients during atrial extrastimulus testing. Of the 17 patients who demonstrated initial block in the His-Purkinje system, ten patients had A-V nodal gap (a type 1 gap). Of these ten patients, progressive increase in A-V nodal conduction was responsible for a resumption of A-V conduction in six patients, dual pathways within the A-V node was responsible in three patients, and the presence of an extra nodal pathway of the A-V node was responsible in one patient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.