Abstract

The human hip capsule is adapted to facilitate upright posture, joint stability, and ambulation, yet it routinely is excised in hip surgery without a full understanding of its mechanical contributions. The objective of this study was to provide information about the mechanical properties of the ligaments that form the hip capsule. Cadaver bone[ndash ]ligament[ndash ]bone specimens of the iliofemoral, ischiofemoral, and femoral arcuate ligaments were tested to failure in tension. The hip capsule was found to be an inhomogeneous structure and should be recognized as being composed of discrete constituent ligaments. The anterior ligaments, consisting of the 2 arms of the iliofemoral ligament, were much stronger than the posterior ischiofemoral ligament, withstanding greater force at failure and exhibiting greater stiffness. Knowledge of the anatomy and mechanical properties of the capsule may help the hip surgeon choose an appropriate surgical approach or repair strategy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.