Abstract

The lumping of the heat transfer parameters of the one- and the two-dimensional pseudo-homogeneous model of a cooled fixed bed were compared. It appeared that the lumping of the two-dimensional parameters, being the effective radial conductivity λ eff and the heat transfer coefficient at the wall α w, into the one-dimensional overall heat transfer coefficient U results in a length dependence of U. It is shown that the ratio α w/ U develops from unity at the bed inlet to a final value. The magnitude of this final value depends on the Biot number, whereas the length of this transition section is affected by the Peclet number. A new relation to lump the effective conductivity and the heat transfer coefficient at the wall into an overall heat transfer coefficient which depends on the values of the Biot number and the Peclet number is presented. This relation accounts for both the magnitude and the transition length of the ratio α w/ U.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.