Abstract

Bromodeoxyuridine (BrdUrd) incorporation and flow cytometry were used to measure human tumour kinetic parameters in vitro and in vivo. The technique was validated by comparison of labelling index estimates of mouse tumours in vivo and in vitro using BrdUrd and flow cytometry with tritiated thymidine (3HdThd) autoradiography. Similar labelling indices were obtained with both in vivo and in vitro incorporation into DNA of the two different precursors. Measurements of human tumour labelling indices were similar following in vitro incubation with either BrdUrd or 3HdThd. The use of BrdUrd allowed the visualization of a population of S-phase cells that did not appear to incorporate BrdUrd or 3HdThd. The human tumour labelling indices obtained with BrdUrd incorporation were similar to previously reported values using autoradiography studies. Preliminary studies demonstrated that significant human tumour labelling could be achieved with an intravenous injection of 500 mg BrdUrd.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.