In this paper, the authors present the results of an investigation into the starting process of a small wattage metal halide lamp and address the influence of the starting process, at extra- high frequency (>350 kHz), upon the performance of two most commonly used electronic ballast circuit topologies, namely the LCC resonant inverter and LCL resonant inverter. The starting transient processes driven by both ballast systems are captured, analyzed and explained. It has been found that the starting process could affect the operating performance of an LCL ballast and may destroy its power switches in the worst case while a LCC ballast gets the advantage over the LCL ballast for the stability during the transient starting process.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.