Abstract

Abstract The article presents results of research on the impact of sensitivity distribution of double transducer probes, which are often used in non-destructive ultrasonic testing of components such as forgings. Distribution of sensitivity measured in two orientations, parallel and perpendicular to the plane of separation of a double transducer probe has been tested and analyzed. A significant influence of orientation of a probe on echo envelope of an artificial point discontinuity has been studied. It has revealed great differences in length and shape of an echo envelope, depending on a type of probe and orientation of a probe separation plane to the moving direction. Eventually, the analysis of practical consequences of dual transducer probes usage for characterization of a type, dimensioning and evaluation of internal discontinuities, in accordance to the methodology specified in EN 10228, has been conducted.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.