Abstract
The influence of pulsed magnet heating on the maximal value of the generated magnetic field is described. The operation of pulsed generator consisting of a capacitor bank, thyristor switch and wire wound pulsed inductor was analysed. The maximum value of the generated magnetic field and pulse duration of pulsed magnet was limited by Joule heating and mechanical stresses. Using Matlab£ Simulink£ software, a flexible model for simulation of thermodynamic processes in pulsed magnet was developed. The calculated results of the maximal value and distribution of magnetic field were verified experimentally and acceptable compliance was achieved using calibrated array of four pick up inductive coils for measurements of axial magnetic field and a current shunt for pulsed current measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.