Abstract
Colonoscopy provides imperfect protection against colorectal cancer and is operator dependent. Colonoscopies typically are poorly documented. We aimed to determine whether videorecording impacts short-term performance of colonoscopy. We videorecorded routine colonoscopies by seven colonoscopists, with and without their awareness. Colonoscopy quality was measured by blinded assessment of inspection time and technique. From pre- to post-awareness of videorecording, mean inspection time increased by 49% for all colonoscopies combined and increased significantly for four individual colonoscopists. The overall quality of mucosal inspection technique improved by 31% after awareness of videorecording. Awareness of videorecording improved physician performance of colonoscopy. Further investigation of the role of videorecording in achieving sustained improvements in the quality performance of colonoscopy, including increases in adenoma detection, is warranted.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.