Abstract

The permitted input power density of rotating anode x-ray sources is limited by the performance of available target materials. The commonly used simplified formulas for the focal spot surface temperature ignore the tube voltage despite its variation in clinical practice. Improved modeling of electron transport and target erosion, as proposed in this work, improves the prediction of x-ray output degradation by target erosion, the absolute x-ray dose output and the quality of diagnostic imaging and orthovolt cancer therapy for a wide range of technique factors. Improved modeling of electronic power absorption to include volume effects and surface erosion, to improve the understanding of x-ray output degradation, enhance the reliability of x-ray tubes, and safely widen their fields of use. We combine Monte Carlo electron transport simulations, coupled thermoelasticity finite element modelling, erosion-induced surface granularity, and the temperature dependence of thermophysical and thermomechanical target properties. A semi-empirical thermomechanical criterion is proposed to predict the target erosion. We simulate the absorbed electronic power of an eroded tungsten-rhenium target, mimicked by a flat target topped with a monolayer of spheres, and compare with a pristine target. The absorbed electronic power and with it the conversion efficiency varies with tube voltage and the state of erosion. With reference to 80kV (100%), the absorption of a severely eroded relative to a pristine target is 105% (30kV), 99% (100kV), 97% (120kV), 96% (150kV), 93% (200kV), 87% (250kV), and 79% (300kV). We show that, although the simplistic Müller-Oosterkamp model of surface heating underestimates the benefit of higher tube voltages relative to operation at 80kV, the error is limited to below -6% for 30kV (reduction advised) and +13% for 300kV (input power increase permitted). Correcting the x-ray conversion efficiency of eroded target material, that is typically not accessible by measuring the tube current, may imply corrections to existing x-ray dose calculations. The relative increase of the allowable anode input power of rotating anode x-ray tubes with increasing tube voltage is substantially smaller than predicted by volume heating models that only rely on the focal spot surface temperature. The widely used voltage agnostic Müller-Oosterkamp formalism fails to predict the tube voltage dependency of the surface temperature of rotating anode targets, ignores the temperature dependency of the thermal diffusivity of tungsten-rhenium, and the granularity of the material. Nevertheless, we show theoretically why, backed by experience, the practical use of the Müller-Oosterkamp formalism is justified in medical imaging and provides a basis for comparison with new microparticle based targets. The reason for this surprising finding is that voltage dependent material erosion must be primarily considered as a precursor of thermal runaway effects.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.