Abstract

The influence of a permanent magnetic field strength up to 40 Gs (4 mT) to operation PMT HAMAMATSU R7899-20 with its standart magnetic screens and without them is investigated. This PMT is used in a hadron calorimeter of LHCb experiment at CERN. It is shown that the use of a protective housing made of steel in joint its use with permalloy screen significantly reduces screening efficiency. It proposed to use a protective housing made from non-magnetic material (duralumin) electrolytic coated with a multilayered film as magnetic shield. This solution can be used in a hadron calorimeter, the CERN installations SHiP.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.