Abstract

Although Cleaning-in-Place (CIP) is abundantly used throughout the food industry, it is recognized that CIP operations use significant amounts of water and energy. The overall objective of this investigation was to evaluate parameters needed to improve the effectiveness of water use during CIP pre-rinse. A pilot-scale CIP system was operated over a range of Reynolds number (Re) from 16,000 to 260,000, while evaluating the effectiveness of rinse water to remove a reconstituted skim milk residue film from stainless steel pipe surfaces. Rinse water effectiveness was quantified by comparing the protein concentration on the pipe surface after pre-rinse to the initial level. As the Re increased, the effectiveness of rinse step increased, but not in linear proportionality. The efficiency of the rinse water decreased significantly as the volume of rinse water increased. The results of this investigation provide the basis for reducing water and energy requirements during CIP operations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.