Abstract

There are well-described impacts of biological rhythms on human physiology. With the increasing push for routine blood tests for preventative medical care and clinical and physiological research, optimizing effectiveness is paramount. This study aimed to determine whether it is feasible to assess diurnal variations of peripheral lymphocyte prevalence using finger prick blood in a small sample size. Using polychromatic flow cytometry, the prevalence of lymphocytes was assessed using 25 µL fingertip blood samples at 8 AM and 5 PM from 8 participants. TH cells and B cells showed significantly higher percentages in the 5 PM samples, whereas NK cells demonstrated a significantly higher morning percentage. T cells, leukocytes, and cytotoxic T cells showed no significant changes. The detection of diurnal variations demonstrates that small blood volumes can be used to detect lymphocyte variations. The lower blood volume required provides a new testing method for clinical and research settings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.