Abstract

The modern polyvinylchloride endotracheal tube (ET) has a large cuff that conforms to the shape of the trachea and can seal it with a low pressure. This large-volume, low-pressure cuffed ET design has, therefore, largely replaced the older red rubber ET which has a small-volume, high-pressure cuff that predisposes to tracheal ischemic complications, particularly during long-term use (1). The new intubating laryngeal mask endotracheal tube (ILM-ET) is an ET used in conjunction with the LMA-Fastrach™ Laryngeal Mask (Euromedical) for blind and fiberoptic-guided tracheal intubation. No specific information is currently available regarding the compliance characteristics of the ILM-ET cuff, which appears to be relatively small. Therefore, this study was designed to measure the compliance of the cuff of the ILM-ET and to compare it with that of the cuff of the polyvinylchloride and red rubber ET. Four size 7.5-mm (inside diameter) of each ET type was tested. The cuff of each tube was incrementally inflated in air, and the corresponding cuff pressure was measured using a calibrated pressure manometer. The ILM-ET cuff clearly exhibited high-pressure characteristics (Figure 1). At cuff volumes used during routine clinical practice, cuff pressure approached 100 mm Hg. Figure 1: The compliance curves of the cuff of three types of size 7.5-mm (inside diameter) endotracheal tubes (ET). Values are mean ± SD. Mallinckrodt, St. Louis, MO; Rüsch, High Wycombe, England; Euromedical, San Diego, CA.During inflation of a low-volume, high-pressure cuff, part of the cuff pressure is consumed in stretching the cuff wall itself. The pressure inside such a cuff is, therefore, higher than the pressure exerted on the tracheal mucosa (CT pressure) by the amount of pressure needed to maintain cuff inflation (2). Nonetheless, when using a low-volume, high-pressure cuffed ET, such as the ILM-ET, it is prudent to attempt to limit the CT pressure. Knowlson and Bassett (3) demonstrated that this could be achieved by inflating the cuff to the minimal volume that sealed the trachea (minimal occlusion volume [MOV]). The authors performed in vivo measurements of CT pressure in patients undergoing anesthesia with a low-volume, high-pressure cuff in place. The CT pressure ranged between 25 and 40 mm Hg at MOV, with a peak inflation pressure of 15 mm Hg and rose rapidly to very high levels with further increments in cuff volume. They concluded from their findings that low-volume, high-pressure cuffs were capable of sealing the trachea with reasonably low CT pressures as long as the cuff was maintained at MOV. The high-pressure characteristics of the cuff of the ILM-ET can be used as an argument against its long term use. Other problems which can be encountered during the long term use of the ILM-ET are the susceptibility to biting and the potential for accumulation of secretions at the reduced-caliber tube tip. In conclusion, the cuff of the ILM-ET is a low-volume, high-pressure cuff. It is, therefore, important when using this ET to maintain its cuff volume at MOV. Esme Riley MD Kerry DeGroot MD Medhat Hannallah MD, FFARCS

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.