Abstract

Abstract A method for the fluorometric determination of gallium in aluminum metal is presented which involves extraction with the methyl isobutyl ketone (MIBK) of the gallium 8-quinolinethiolate complex. The extracted complex has a greenish-yellow fluorescence, with an emission maximum at 505 nm. The maximum fluorescence intensity is obtained at a pH of the initial aqueous phase of around 3.3; the fluorescence remains stable for at least 2 hr. When 50 ml of a sample aqueous solution containing gallium and 0.2 ml of a 0.2% 8-quinolinethiol solution is subjected to extraction with 10 ml of MIBK, the quantity of gallium which can be present for determination in the sample solution amounts to 1 to 30 μg. For the removal of the interfering effects of zinc, cadmium, copper, and nickel on the fluorometric determination, gallium was extracted with isopropyl ether from a 7 M HCl solution. The relative error of this method was 5% for 0.019% gallium in aluminum metal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.