Abstract
The lateral lumbar interbody fusion (LLIF) technique is used to treat many common spinal degenerative pathologies including kyphoscoliosis. The use of spinal navigation for LLIF has not been broadly adopted, especially in adult spinal deformity. The purpose of this study was to evaluate the feasibility as well as the intraoperative and navigation-related complications of computer-assisted 3D navigation (CaN) during multiple-level LLIF for spinal deformity. Retrospective analysis of clinical and operative characteristics was performed for all patients > 18 years of age who underwent multiple-level CaN LLIF combined with posterior instrumentation for adult spinal deformity at the University of Michigan between 2014 and 2020. Intraoperative CaN-related complications, LLIF approach-related postoperative complications, and medical postoperative complications were assessed. Fifty-nine patients were identified. The mean age was 66.3 years (range 42-83 years) and body mass index was 27.6 kg/m2 (range 18-43 kg/m2). The average coronal Cobb angle was 26.8° (range 3.6°-67.0°) and sagittal vertical axis was 6.3 cm (range -2.3 to 14.7 cm). The average number of LLIF and posterior instrumentation levels were 2.97 cages (range 2-5 cages) and 5.78 levels (range 3-14 levels), respectively. A total of 6 intraoperative complications related to the LLIF stage occurred in 5 patients. Three of these were CaN-related and occurred in 2 patients (3.4%), including 1 misplaced lateral interbody cage (0.6% of 175 total lateral cages placed) requiring intraoperative revision. No patient required a return to the operating room for a misplaced interbody cage. A total of 12 intraoperative complications related to the posterior stage occurred in 11 patients, with 5 being CaN-related and occurring in 4 patients (6.8%). Univariate and multivariate analyses revealed no statistically significant risk factors for intraoperative and CaN-related complications. Transient hip weakness and numbness were found to be in 20.3% and 22.0% of patients, respectively. At the 1-month follow-up, weakness was observed in 3.4% and numbness in 11.9% of patients. Use of CaN in multiple-level LLIF in the treatment of adult spinal deformity appears to be a safe and effective technique. The incidence of approach-related complications with CaN was 3.4% and cage placement accuracy was high.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.