Abstract

The aim of this study was to evaluate the diagnostic performance of strain ratio elastography in the assessment of retrobulbar orbital fat tissue. The retrobulbar fat tissue of 14 eyes in 14 participants was scanned by sonoelastography. All the participants had permanent vision loss secondary to glaucoma in at least one eye. The elasticity scores were determined and the strain ratio was based on the comparison of the average strain measured in the retrobulbar fat tissue around the optic nerve at the same depth. The mean strain values for the optic nerve (B) and the retrobulbar fat tissue (A) were 0.78+/-0.61 and 1.43+/-0.99, respectively (p=0.005). The mean strain ratio (B/A) was 0.56+/-0.24. This preliminary study showed that by providing strain values and ratios of different orbital tissues sonoelastography may have a potential use in the diagnosis and follow-up of orbital inflammatory and infiltrative diseases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.