Abstract

Beef primals and retail joints were rapidly heated and cooled using steam condensation and evaporation heat transfer processes. Treatments of beef primals to 100 or 120 °C showed no significant differences. After 3 weeks of vacuum-packed storage at 0 °C, mean total viable count (TVC) and enterobacteriaceae counts for treated primals were approximately 1 log 10 cfu cm −2 lower than for un-treated primals. Levels were similar after 6 weeks of vacuum-packed storage. The effects of a second treatment on retail joints cut from treated and un-treated primals that had been stored in vacuum packs for 3 weeks showed TVC and enterobacteriaceae counts for treated joints were approximately 1 log 10 cfu cm −2 lower than for un-treated joints after 4 and 8 days of over-wrapped storage. The results suggest the steam decontamination treatment used can remove small but significant ( p < 0.05) numbers of bacteria from the beef surface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.