Abstract

An experimental study is carried out to investigate the effects of nozzle aspect ratio and nozzle number on the performance of a vortex tube. Two sets of vortex generator (a single nozzle set with aspect ratio of AR = 0.25, 0.44 and 0.69 and a multiple nozzle set with 2 and 3 nozzle number having the same total flow area) are tested under different inlet pressures. Dry air is used as the working fluid. The experimental results reveal that the nozzle aspect ratio has a great effect on the energy/temperature separation mechanism. The increase in the nozzle aspect ratio leads to the larger mixing zones, which, in turn, decreases the temperature difference between the cold and hot stream, the heating and the cooling performance. The results also showed that the vortex tube with a single nozzle yields better performance than the vortex tube with 2 and 3 nozzles.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.