Abstract

Although flexible ureteroscopes are designed with mechanisms for active and passive tip deflection, one of the major problems is the not infrequent inability to enter the lower pole calices. Accordingly, we measured the change in the lower pole infundibulopelvic (LIP) angle when the patient's position was varied (i.e., prone, supine, head down) during intravenous urography (IVU). The LIP angle was measured in 20 right and 26 left adult kidneys during an IVU with the patient in six different positions: supine level, supine 20 degrees head down, supine 45 degrees head up, prone level, prone 20 degrees head down, and prone 45 degrees head up. None of the patients had a history of renal surgery. In all cases, the broadest angle of entry to the lower pole infundibulum was obtained with the patient in a prone position and 20 degrees head down. The LIP angle broadens when the patient lies in a prone 20 degrees head down position. This maneuver could improve the surgeon's ability to access the lower pole calices when performing flexible ureteronephroscopy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.