Abstract

Abstract The effect of particle size on the regional deposition of aerosols inhaled through the mouth was determined in 93 studies on 34 subjects. The test aerosols were spherical monodisperse insoluble iron oxide particles (specific gravity 2.5) containing radioactive tags, ranging in median unit density diameter from 2.1 to 12.5-microns (σ ≅ 1.08). Particles deposited on the bronchial tree were translocated to the stomach by mucociliary clearance which was essentially complete within the first day. The proportion of the initial lung burden of radioactive particles removed during the first 24 hours provided a functional measure of tracheo-bronchial deposition. A portion of the inhaled aerosol was deposited in the head by impaction. As an impactor, the tracheobronchial tree is more efficient. For each individual subject, head and tracheobronchial deposition increased with increasing particle size. Alveolar depositions decreased with size for particles larger than 4-microns.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.