Abstract

Experimental results are presented of the effects of flow distortions, generated by a compressor cascade, on the performance of a short annular dump-diffuser type combustor inlet. The distance between the cascade and the diffuser entrance plane was varied. The losses increase substantially when this distance becomes small. In most of the tests the losses turned out to be minimum at a distance of about two blade-chord lengths. When the cascade was removed, the losses were higher than this minimum value. Evidence is presented that the radial blockage factor rather than the total blockage factor determines the magnitude of the losses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.