Abstract

In one optic nerve from each of 19 persons, the authors determined the number of axons, the distribution of fiber diameter, and the total neural area. The mean fiber count was 693,316, the mean neural area was 5.17 mm2, and the mean axonal fiber diameter was 0.96 µm. No significant decline in fiber number or neural area with increasing age was found. The authors found a large variability of axonal number among their patients. This variability would have obscured any small effect of aging. Linear regression analysis of the effect of age on mean axonal diameter yielded a slight negative slope (P < 0.10), suggesting a redistribution of fiber diameter. This could occur from axonal shrinkage, from preferential large fiber loss, or from the technical features of tissue acquisition and analysis. The authors suspect that the explanation is a selective loss of large nerve fibers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.