Abstract
Objective To evaluate the cut-off points and diagnostic value in keratoconus of the ultra-high frequency Scheimpflug corneal biomechanical analyzer. Methods In this descriptive study, the same operator, using the same biomechanical analyzer, measured the 12 parameters of 93 keratoconus eyes and 84 control eyes. From Eye Hospital of Wenzhou Medical University during December 2013 to July 2015. The subjects were staged with the Amsler-Krumeich keratoconus classification. Differences of parameters between the two groups were analyzed, and the cut-off points (COP) for the parameters between the groups was analyzed by receiver operating characteristic (ROC) curves. The area under the curve (AUC) method was used to evaluate the diagnostic value of the 12 parameters. Results Except for applanation 1 length (AP1 L), applanation 2 time (AP2 T), and maximum deformation amplitude (A), all other parameters were significantly different between the keratoconus and the control eyes (P 0.17 m/s, applanation 2 length (AP2 L) ≤1.49 mm, applanation 2 velocity (AP2 V) >0.42 m/s, peak distance (PD) ≥ 4.78 mm, A >1.24 mm, maximum deformation curvature (C) ≤5.66 mm, maximum deformation time (T) ≤16.40 ms, intraocular pressure (IOP) ≤13.50 mmHg, and central corneal thickness (CCT) ≤494 μm. Of all the parameters, C, AP1 V, and T had a medium level of diagnostic value. For these parameters, the AUC values were 0.738 (sensitivity 47.3%, specificity 94.0%), 0.751 (sensitivity 61.3%, specificity 88.1%), and 0.887 (sensitivity 77.4%, specificity 91.7%), respectively. The CCT and PD had good diagnostic values, with AUCs of 0.926 (sensitivity 82.4%, specificity 92.9%) and 0.930 (sensitivity 92.5%, specificity 85.7%), respectively. Conclusion Some of the CorVis-ST parameters have medium to good diagnostic value for keratoconus, while the CCT and PD have good diagnostic value. This suggests that the CorVis-ST could provide useful assistance in the clinical diagnosis of keratoconus. Key words: Keratoconus; Scheimpflug; Receiver operating characteristic curve; Cutting-off point
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.