Abstract

This study creates a deterioration diagnostic model for the external wall tiles of aged buildings, using both stage 1 and stage 2 diagnostic methods. The visual test results are categorized based on their impact on public safety, and renovation strategies are proposed. The stage 1 diagnosis mainly adopts the D.E.R. visual inspection the deterioration assessment method. After producing an external wall tile Condition Indicator (CI) for the stage 1 diagnostic results that fall in a gray area, this research performed a stage 2 diagnosis using a tap tone test, followed by a fast Fourier transform and pattern recognition to analyze the tapping results. Finally, this study provides deterioration evaluation criteria for external wall tile replacement recommendations and a standard operating procedure for the deterioration diagnosis. This study also suggest directions for the future amendment of regulations and provide a basis of references for the government in determining urban renewal, renovation and maintenance strategies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.