Abstract

Abstract Pumping speed measurements in the continuum pressure region, P >10 −3 torr, have been made for water vapour impinging on copper spheres and coils cooled to liquid nitrogen temperatures. Water vapour flow rates between 0.06 mg s −1 and 420 mg s −1 were used. The volumetric pumping speed was constant over the pressure range 2 × 10 −3 torr to 2 × 10 −2 torr and was, as expected, higher than that obtained in the free molecular flow region. Above 2 × 10 −2 torr the pumping speed decreased and possible reasons for this were investigated and are discussed. These included the effects of inadequate heat transfer from the liquid nitrogen refrigerant to the cryopump, a poor thermal conductivity of the cryodeposit, and an impurity, nitrogen gas, in the water vapour.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.