Abstract

Cardiac pacing is an effective treatment for patients with bradycardia due to sinus node dysfunction or atrioventricular block. Despite decades of technological advances, the optimal ventricular pacing site to mimic normal human ventricular physiology and best hemodynamic response remains elusive. Beginning with atrial synchronous right ventricular (RV) apical pacing, the search has continued through alternate RV pacing sites, minimizing RV pacing, biventricular pacing, left ventricular (LV) pacing, and His-bundle pacing. Understanding the deleterious effects of long-term RV apical pacing in vulnerable populations has created tremendous interest in alternate pacing options. This paper reviews the current status of available pacing options, with particular focus on His-bundle pacing. Permanent His-bundle pacing has emerged as the leading candidate for physiological pacing because it provides nearly normal electrical activation of both ventricles and thereby avoids ventricular dyssynchrony. Synchronized LV pacing, multisite LV pacing, and LV endocardial pacing offer promise as novel pacing options in select patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.