Abstract

A high precision clock system is required in the external target experiment of the Cooling Storage Ring (CSR) project in the Heavy Ion Research Facility in Lanzhou (HIRFL). Considering that the detectorsare located in different places of the experimental hall, a high quality clock signal is required to be generated and distributed to multiple measurement modules over long distances. The clock system is based on a master-slave structure: the slave clock module (SCM) receives the clock signal from the master clock module (MCM) through fiber, and then distributes it to the measurement modules within the same PXI crate. Laboratory test results indicate that the period jitter and cycle-to-cycle jitter of this clock system is better than 5 ps and 8.5 ps respectively. We also conducted tests on the TOF (time of flight) readout modules (with the highest time measurement resolution in the readout electronics) combined with this clock system, and a time resolution better than 25 ps is achieved, beyond the requirement. Keywords-cycle to cycle jitter; period jitter; clock skew; LVDS; clock system

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.