Abstract

The geometry of a single aperture in the extraction grid plays a relevant role for the optimization of negative ion transport and extraction probability in a hybrid negative ion source. For this reason, a three-dimensional particle-in-cell/Monte Carlo collision model of the extraction region around the single aperture including part of the source and part of the acceleration (up to the extraction grid (EG) middle) regions has been developed for the new aperture design prepared for negative ion optimization 1 source. Results have shown that the dimension of the flat and chamfered parts and the slope of the latter in front of the source region maximize the product of production rate and extraction probability (allowing the best EG field penetration) of surface-produced negative ions. The negative ion density in the plane yz has been reported.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.