Abstract

We report a simple technique for the measurement of energy losses in HTS tape carrying ac currents in ac magnetic fields at liquid nitrogen temperatures. This method is based on measuring the temperature rise of a thermally insulated tape and in the present form is able to measure losses down to 0.01 W m −1. We present data obtained by this method confirming previously published results for the losses at 100 Hz due to in phase ac currents and magnetic fields as measured electrically. Using this calorimetric method we are able to measure the effect of phase differences between current and field.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.