An integral formulation is derived from the Biot-Savart law in conjunction with Gaussian numerical integral methods and applied to the computation of magnetic fields surrounding a two-wire twisted-pair transmission line in the static case. The results show the effects of the length of the pitch of the twisted-pair line on magnetic fields surrounding these lines and the 3-D nature of this field. It appears that, to obtain uniform heating, one should try different shapes for the exciting coils. Increasing the length of the heating coils improves the uniformity near the center of the workpiece, but has the effect of overheating at the edges. Changing the distance between the coils or the supply frequency does not have a significant effect on the heating pattern. The significance of the analysis lies in its relation to electromagnetic compatibility considerations which must be taken into account in the design of the electric power transmission and distribution system of NASA's Space Station Freedom (SSF). >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.