Abstract

Six consecutive patients whose clinical Allen test suggested a non-patent radial artery have been investigated by intra-arterial fluorescein angiography. Cannulation of the radial artery and injection of fluorescein typically perfused only the thumb and thenar eminence. Occlusion of the ulnar artery, leaving the radial artery as the dominant supply, resulted in fluorescein perfusion of the entire hand. It is concluded that the Allen test is of no clinical value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.