Abstract
A 3D contact analysis and modeling suite of tools are developed and introduced in this work. The “3D Contact Map” of an electrical contact interface is presented demonstrating the 3D nature of the contact. It gives information on where the electrical contact spots in a 3D surface profile are located. An X-ray Computer Tomography (CT) technique is used to collect the 3D data to a resolution of around 5μm of a real un-dismantled contact interface for analysis. Previous work by Lalechos and Swingler presented “2D Contact Map” on a 2D contact profile from collected 3D data to a resolution of around 8μm. The main advantages of both 3D and 2D mapping techniques focus on the fact that they are non-destructive and there is no need to dismantle the component of interest. This current work focuses on the 3D mapping technique showing its advantages over the 2D mapping technique. For test purposes, a 16A rated AC single pole switch is scanned after two different current loading tests (0A and 16A). A comparison for the total mechanical area of contact, the number of contact spots and the total contact resistance is conducted using both the 2D and 3D mapping techniques to a resolution of around 5μm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.