Abstract

Purpose: To evaluate the accuracy of our rigid and non‐rigid registration methods to align three‐dimensional (3D) transrectal ultrasound (TRUS) images of the prostate in order to improve repeat biopsy planning and guidance for prostate cancer diagnosis. Methods and Materials: Three 3D prostate ultrasound images were obtained from each of the 16 patients during 3D prostate ultrasound‐guided biopsy procedures. These 3D images had identifiable calcifications and cysts, which were used as fiducials for the registration validation. For each prostate, images at two different time points (to and t1) during the procedure were selected and the 3D coordinates of the identified fiducials were recorded. A total of 62 fiducials were identified. All images were then segmented manually and semi‐automatically. Images at to were registered to the corresponding images at t1 using rigid and non‐rigid registration. Rigid and non‐rigid registration was performed using boundary‐based iterative closest point and thin‐plate spline algorithms, respectively. We evaluated the registration methods by determining the target registration error (TRE), effect of segmentation variability on registration variability, the TRE dependence on fiducial distance from the transducer tip, and the fiducial localization error (FLE). Results: Tests showed that the FLE was 1.3mm. The mean TRE for manual and semi‐automatic segmentation was 2.2mm and 2.3mm respectively in both rigid and non‐rigid cases. There was little correlation between the TRE and the distance of the fiducials from the ultrasound transducer tip, and segmentation variability resulted in a 0.57mm standard deviation of the TRE. Conclusions: Our results suggest that both rigid and non‐rigid registration techniques for 3D TRUS images during a biopsy procedure are accurate to within 2.3mm, which is less than the 5mm radius of the smallest tumors considered clinically significant. Future tests will evaluate registration accuracy for multimodal cases, specifically magnetic resonance to ultrasound images.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.