Abstract
As part of a multistate research program on use of high-performance concrete (HPC) in highway bridges, a bridge originally designed as a three-span adjacent box girder bridge was converted to a single-span bridge by using 70-MPa HPC and 15-mm strands. As part of the research, a test beam was constructed and tested. Instruments placed in the beam before casting were used to measure transfer length, which was found to be approximately 1.22 m, larger than the 50-bar diameters usually used in the American Association of State Highway and Transportation Officials (AASHTO) Standard Specifications but consistent with recent studies. After the beam concrete reached the required compressive strength, it was tested to destruction. The beam was able to resist the required AASHTO ultimate moment without failure. It was found that the AASHTO cracking load was conservative for this beam, mostly because the measured modulus of rupture greatly exceeded the value assumed in the AASHTO specifications. The behavior of the beam was successfully predicted using a section analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transportation Research Record: Journal of the Transportation Research Board
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.