Abstract

Abstract The present study aims to investigate flue gas emissions, particularly pollutants CO, NO x and particle emissions, of a domestic biomass boiler under various operating conditions. The experimental methodologies are systematically introduced. If the primary and secondary air supply for the biomass furnace are provided by the factory-set openings and vent tubes, the flue gas emissions measured are NO x 54.92 ppmv, CO 2 11.98 vol%, CO 0.24 vol%, O 2 8.19 vol% and PM 0.1–10 concentrations 72.7 mg/Nm 3 by burning wood pellets. In addition, the three kinds of cleaning technologies reducing particle emissions are also introduced.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.