Abstract
Within the framework of the European Fusion Programme a contract has been awarded to the Karlsruhe Nuclear Research Centre for the investigation of the compatibility with graphite dust of the elastomer-sealed vacuum valves under tokamak operating conditions. Three types of elastomer seal (VITON, BUNA-N and EPDM) are investigated in the SPARTA test facility. A seal tightness of <10 −6 mbar l s −1 is measured despite dust loading of up to 80% and a particle mean diameter of the dust agglomerates of up to 100 ωm. The experimental results obtained are discussed in this paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.