Abstract

Abstract Details of an experiment are given in which 10-foot lengths of pipe were buried in Canada at depths of 1 through 5 feet after application of five systems of coatings and wrappings on groups of 5 pipes each. Pipes were buried after testing with an electronic holiday detector with self-registering thermometers in two pipes at each level. After a year's exposure the pipes were unearthed and tested electrically for holidays. Only a limited number of holidays were found and they were not apparently related in any way to the kind of coating or severity of exposure. Temperatures registered ranged from 25 F to 34 F. increasing with depth. Another test of pipes exposed to atmosphere but protected from the elements was made. Results after a year showed that although temperatures of —8 F had been reached, holidays were few except in sections unwrapped but coated with unplasticized enamel. The advantages of wrapping in protecting the coating were obvious. 5.4.5

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.