Abstract

The objective of this study was to test a new in-kiln sensor for monitoring lumber moisture content during industrial drying. The theoretical foundation of the technology was already known, because it is based on electrical conductivity, but the mechanism of implementation was new and required validation. For this reason, the technology was compared with two other widely used methods for assessing lumber moisture content, namely, the oven-drying and electrical capacitance methods. The tests were performed in a 120-m3 industrial kiln operated by a sawmill in the eighth region of Chile, and the results showed that the average moisture content at the end of drying was satisfactorily determined by the new in-line sensor. As predicted by theory, the sensor was not able to accurately measure moisture content above 25%, but it was still able to provide the equivalent of a drying curve for monitoring of the drying process.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.