Abstract
Results of beam tests of a prototype drift chamber vertex detector developed for the D-Zero experiment at the Fermilab collider are reported. The chamber design emphasizes dual goals of high accuracy position measurement and excellent two track resolution. These requirements are met by using a slow gas, dimethyl ether, in a jet chamber geometry with a double plane of field-shaping wires near the anodes. Resolution of nearby hits is facilitated by 100 MHz flash digitization of the signal pulses. The prototype tested consisted of a full-length (97 cm) model of one azimuthal sector of the innermost layer of the detector, with 8 anode wires. Position measurement accuracy of 30–80 μm for drift distances of 2–11 mm and pulse pair resolution of 0.7 mm (for 90% of all pulses) is achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.