Abstract

In the scope of this paper, tensile capacities of post-installed chemical anchors embedded to 5.9 and 10.9MPa concrete blocks are investigated. Pull-out tests are applied to 80 ductile steel bars (S420a). For the anchor diameters, 12, 16 and 20mm are chosen. On the other hand, 10, 15 and 20times the bar diameter are selected as free-edge distance and embedment depth for monotonic tensile loading tests. The results indicate that installation of anchors into low-strength concrete with sufficient embedment depth and free-edge distance is not unsafe as previously expected. To obtain ductile failure in low strength concrete, free-edge distance and embedment depth of minimum 15times the anchor diameter should be required. Furthermore, a comparison of test results with ACI 318 capacities is done and it is observed that ACI 318 has quite an over-conservative approach for the tensile capacity of post-installed anchors when low-strength concrete is considered.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.