Abstract

We present a study of the temporal prepulse contrast degradation of high focused intensity pulses produced in CPA laser systems due to imperfections in amplifier design, alignment of amplifier components, and crystal inhomogeneity. Using an extended cross-polarized imaging technique, we demonstrate the presence of multiple crystal domains inside Ti:sapphire slabs with ≈10cm diameter. The results of our numerical calculations show that crystalline c-axis orientation inhomogeneity caused by these crystal domains can lead to the generation of prepulses with a relative contrast of >10-10 within several picoseconds before the main pulse. In a multiple-slab amplifier head configuration sometimes used in high-repetition-rate systems, the misalignment of the crystalline c-axes of the amplifier slab with respect to each other can lead to the generation of prepulses with relative contrast as high as 10-6, depending on the magnitude of misalignment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.