Abstract

The ferritic stainless steel AISI 441 (EN 1.4509) is exposed for 1000 h to air - 3% H2O on one side and to Ar - 5% H2 – 3% H2O on the other at temperatures 600, 700, and 800 °C. Conditions are chosen to mimic the environment of metallic interconnects in an operating solid oxide fuel cell (SOFC). At 600 °C, ∼25 μm thick Fe2O3/(Fe,Cr)3O4 forms on large parts of the air side of the samples. Reference samples exposed to air - 3% H2O on both sides form thin protective layers of (Cr,Mn)3O4/Cr2O3 at the same temperature. At higher temperatures, 700 and 800 °C, all samples form protective layers of (Cr,Mn)3O4/Cr2O3 regardless of exposure to single or dual atmosphere. It is concluded that corrosion resistance in a dual atmosphere has an inverse dependence on temperature. Different hypotheses for the underlying cause for the dual atmosphere effect are discussed and compared to the experimental data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.