Abstract

Repeated falling weight deflectometer (FWD) tests were conducted at three sites. The tests were conducted at regular intervals for 2 to 3 consecutive days per location, and also done during different seasons in order that the widest possible range of temperatures could be obtained. The influence of cracks on temperature correction was also investigated. Temperature correction equations for deflection and moduli were developed so that users could be allowed to input their own reference temperatures. For all test pads, only the W1 and W2 deflections were found to be significantly affected by temperature. Comparisons with other reported temperature correction equations showed close agreement for deflection, but not for moduli. Tests were also run on cracked locations. Temperature did not affect the response of the cracked pavement as much as it did the intact pavement. Due to the different temperature-dependent characteristics of intact and cracked locations, the equations developed from the intact locations may not be used on cracked locations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.