Abstract
The generator is the starter device of single stage heat transformer (SSHT) and its characteristics have main effects on the overall efficiency of this kind of absorption machines. This article reports a study of the generation of steam and changes in the concentration of the working solution (Water/Carrol mixture) into a plate heat exchanger as a function of its horizontal and vertical position by gravity effect. It is considered the analysis of six experimental tests; two were evaluated in a plate heat exchanger in a horizontal position and four in a vertical position (90 degree inclination). The generation of steam and increased concentration of the working solution are more sensitive to the vertical position of exchanger than in horizontal position. The results of numerical-experimental analysis indicates that a heat exchanger in horizontal position, the steam generation and the change in the concentration of the working solution occurring in the middle of the plate (or at greater distance depending to the thermodynamic conditions) and instantly in vertical position (at the input of the plate).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.