Abstract

A method for measuring power line impedances using two current probes is examined. This method is characterized by good isolation of the measurement equipment from the power line voltage and by the capability of measuring power line impedances between any pair of power-plug terminals. The use of this two-current probe method with the model described is effective in measuring power line impedances from 0.5 MHz to 100 MHz. Using purely resistive loads for calibration, the error is less than 5% for frequencies below 100 MHz, and less than 20% for frequencies between 100 MHz and 500 MHz. The error in an impedance measurement increases with the magnitude of the load impedance.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.