Abstract

BackgroundMammaTyper is a novel CE-marked in vitro diagnostic RT-qPCR assay which assigns routinely processed breast cancer specimens into the molecular subtypes Luminal A-like, Luminal B-like (HER2 positive or negative), HER2 positive (non-luminal) and Triple negative (ductal) according to the mRNA expression of ERBB2, ESR1, PGR and MKI67 and the St Gallen consensus surrogate clinical definition. Until now and regarding formalin-fixed, paraffin-embedded material (FFPE), this has been a task mostly accomplished by immunohistochemistry (IHC). However the discrepancy rates of IHC for the four breast cancer biomarkers are frequently under debate, especially for Ki-67 which carries the highest degree of inter- and even intra-observer variability. Herein we describe a series of studies in FFPE specimens which aim to fully validate the analytical performance of the MammaTyper assay, including the site to site reproducibility of the individual marker measurements.MethodsTumor RNA was extracted with the novel RNXtract RNA extraction kit. Synthetic RNA was used to assess the sensitivity of the RNXtract kit. DNA and RNA specific qPCR assays were used so as to determine analyte specificity of RNXtract. For the assessment of limit of blank, limit of detection, analytical measurement range and PCR efficiency of the MammaTyper kit serial dilutions of samples were used. Analytical precision studies of MammaTyper were built around two different real time PCR platforms and involved breast tumor samples belonging to different subtypes analyzed across multiple sites and under various stipulated conditions. The MammaTyper assay robustness was tested against RNA input variations, alternative extraction methods and tumor cell content.ResultsIndividual assays were linear up to at least 32.33 and 33.56 Cqs (quantification cycles) for the two qPCR platforms tested. PCR efficiency ranged from 99 to 109 %. In qPCR platform 1, estimates for assay specific inter-site standard deviations (SD) were between 0.14 and 0.20 Cqs accompanied by >94 % concordant single marker assignments for all four markers. In platform 2, the inter-site SD estimates were between 0.40 and 0.66 Cqs while the concordance for single marker assignments was >94 % for all four markers. The agreement reached between the two qPCR systems located in one site was 100 % for ERBB2, 96.9 % for ESR1, 97.2 % for PGR and 98.6 % for MKI67. RT-qPCR for individual markers was stable up to a 64-fold dilution for a typical clinical sample. There was no change in assay performance detected at the level of individual markers or subtypes after using different RNA isolation methods. The presence of up to 80 % of surrounding non-tumor tissue including in situ carcinoma did not affect the assay output. Sixteen out of 20 RNXtract eluates yielded more than 50 ng/μl of RNA (average RNA output: 233 ng/μl), whereas DNA contamination per sample was restricted to less than 15 ng/μl. Median recovery rate of RNA extraction was 91.0 %.ConclusionsIn this study the performance characteristics of MammaTyper were successfully validated. The various sources of analytical perturbations resulted in negligible variations in individual marker assessments. Therefore, MammaTyper may serve as a technical improvement to current standards for decentralized FFPE-based routine assessment of the commonly used breast cancer biomarkers and for molecular subtyping of breast cancer specimens.Electronic supplementary materialThe online version of this article (doi:10.1186/s12885-016-2476-x) contains supplementary material, which is available to authorized users.

Highlights

  • MammaTyper is a novel CE-marked in vitro diagnostic Reverse-transcription quantitative real time PCR (RT-qPCR) assay which assigns routinely processed breast cancer specimens into the molecular subtypes Luminal A-like, Luminal B-like (HER2 positive or negative), human epidermal growth factor receptor 2 (HER2) positive and Triple negative according to the mRNA expression of Receptor tyrosine-protein kinase erbB-2 gene/mRNA (ERBB2), Estrogen receptor gene/mRNA (ESR1), Progesterone receptor gene/ mRNA (PGR) and Marker of proliferation Ki-67 gene/mRNA (MKI67) and the St Gallen consensus surrogate clinical definition

  • The agreement reached between the two qPCR systems located in one site was 100 % for ERBB2, 96.9 % for ESR1, 97.2 % for PGR and 98.6 % for MKI67

  • MammaTyper may serve as a technical improvement to current standards for decentralized FFPE-based routine assessment of the commonly used breast cancer biomarkers and for molecular subtyping of breast cancer specimens

Read more

Summary

Introduction

MammaTyper is a novel CE-marked in vitro diagnostic RT-qPCR assay which assigns routinely processed breast cancer specimens into the molecular subtypes Luminal A-like, Luminal B-like (HER2 positive or negative), HER2 positive (non-luminal) and Triple negative (ductal) according to the mRNA expression of ERBB2, ESR1, PGR and MKI67 and the St Gallen consensus surrogate clinical definition. Immunohistochemistry (IHC), pTNM staging and clinical characteristics have traditionally been used to estimate a patient’s risk of relapse and long-term outcome and provide indications on (neo)adjuvant treatment. In recent years molecular profiling of breast cancer has prompted actions towards more precise stratification of individual patients and more informed treatment decisions [2]. The so called “intrinsic” subtypes (Luminal A, Luminal B, HER2-positive and Basal-like), not unrelated to long-established breast cancer phenotypes, likely represent separate diseases with distinct underlying biology and clinical characteristics. The exact determination of these molecular subtypes may enhance the prognostic power of traditional clinicopathological parameters [3]

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.