Abstract
AISC Seismic Provisions Section E6.4b for steel special cantilever column systems (SCCS) requires clarification based on inquiries to the AISC Steel Solution Center. In the 2016 edition, it is unclear if bracing is required for all special cantilever columns or for columns with unbraced lengths that exceed the maximum beam brace spacing of Lb per Section D1.2a for moderately ductile members. Instead of using Equation D1-2, which is applicable to I-shaped beams only, equations for SCCS columns have been derived for both I-shaped members and rectangular HSS or box-shaped members. The proposed revision provides specific situations when bracing is required.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.