Abstract
Details are presented in the preparation of T-section specimens for determining the tensile tearing strengths of web–flange junctions of two sizes of pultruded glass reinforced plastic GRP wide flange (WF) profiles. Two simple test rigs, used to carry out the tension tests on the web–flange junctions, are described. The tensile tearing strengths derived from 43 tests are presented and the characteristic failure mode of the web–flange junction is explained. It is shown that the tearing strengths of the junctions of the smaller WF profile are larger than those of the larger WF profile and, moreover, that they are only about one-quarter to one-third of the minimum transverse tensile strength of the material given the manufacturer's design manual.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Composites Part A: Applied Science and Manufacturing
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.